Product Profile:
- - Mobile Home Feeder Cable
- - 600 Volt
- - Aluminum Alloy (AA-8176) Conductor
- - Cross-linked Polyethylene (XLP) Insulation
- - Sunlight Resistant
Manufacturer: Joy Sense - World Fourth Largest Aluminum Alloy Cable Manufacturer
Applicaitons:
- - Joysense Mobile Home Feeder is intended for the connection of mobile homes to a supply of electricity where permanent wiring is required as specified in the NEC®1
- - Suitable for direct burial in earth at conductor remperatures not to exceed 90 Celsuis Degrees.
- - Voltage rating is 600V
- - Three sizes available (with and without reduced neutral): 100, 150, and 200 ampere ratings.
Standards & References:
Individual conductors of Joysense Mobile Home Feeder assembly meet or exceed UL Standard 44, UL Standard 854, Federal Specfication A-A-59544, and requirements of the NEC®.
Construction:
Joysense Mobile Home Feeder consists of four quadruplexed type RHH or RHW-2 or USE-2 with AA-8000 series Aluminum Alloy compacted conductors. The cable contains a triple extruded white strped neutral conductor and a solid green grounding conductor to elimiate the need for field marking per the NEC®. Insulation is sunlight resistant.
Recommended Sample Specifications:
Cable shall be UL-listed Type RHH or RHW-2 or USE-2, suitable for direct burial and operation at 600V. Conductors shall be Aluminum Alloy as manufactured by Joysense Company or approved equal. The calbe shall contain a triple extruded white striped neutral conductor and a sold green grounding conductor to eliminate the need for field marking per the NEC®.
WEIGHTS, MEASUREMENTS AND PACKAGING |
|||||||||||||
CONDUCTOR SIZE (AWG or kcmil) |
PHASE CONDUCTOR |
NEUTRAL CONDUCTOR |
GROUNDING CONDUCTOR |
COMPLETE CABLE O.D.(mils) |
WELGHT PER 1000ft (lbs) |
ALLOWABLE AMPACITY |
STD. PKG (ft) |
||||||
SIZE& CONST. |
INS. THICK (mils) |
DIA. (mils) |
SIZE& CONST. |
INS. THICK (mils) |
DIA. (mils) |
SIZE& CONST. |
INS. THICK (mils) |
DIA. (mils) |
|||||
2-2-4-6 |
2-7 |
60 |
391 |
4-7 |
60 |
336 |
6-7 |
60 |
292 |
944 |
305 |
100 |
500 |
2-2-2-4 |
2-7 |
60 |
391 |
2-7 |
60 |
391 |
4-7 |
60 |
336 |
944 |
351 |
100 |
500 |
2/0-2/0-1-4 |
2/0-18 |
80 |
539 |
1-18 |
80 |
462 |
4-7 |
60 |
336 |
1301 |
561 |
150 |
500 |
2/0-2/0-2/0-1 |
2/0-18 |
80 |
539 |
2/0-18 |
80 |
539 |
1-18 |
80 |
462 |
1301 |
679 |
150 |
500 |
4/0-4/0-2/0-4 |
4/0-18 |
80 |
638 |
2/0-18 |
80 |
539 |
4-7 |
80 |
462 |
1540 |
793 |
200 |
500 |
4/0-4/0-4/0-2/0 |
4/0-18 |
80 |
638 |
4/0-18 |
80 |
638 |
2/0-18 |
80 |
539 |
1540 |
999 |
200 |
500 |
Dwelling-For units, conductors shall be permitted at listed ampacities as 120/240 volt, 3-wire, single-phase services and feeders. All conductors are compact stranded construction complying with UL standard 44. |