产品中心
北京市朝阳区霞光里15号霄云中心B座1905室
电话: 010-84519511 、84519122
传真: 010-84514688
邮箱: info@luminovogroup.com
Mobile Home Feeder : Aluminum Alloy Cable Series
日期: 2014-09-23 15:48:24    点击量:

 

 

  Product Profile: 

  • - Mobile Home Feeder Cable
  • - 600 Volt
  • - Aluminum Alloy (AA-8176) Conductor
  • - Cross-linked Polyethylene (XLP) Insulation
  • - Sunlight Resistant

 

Manufacturer: Joy Sense - World Fourth Largest Aluminum Alloy Cable Manufacturer

 

Applicaitons:

  • - Joysense Mobile Home Feeder is intended for the connection of mobile homes to a supply of electricity where permanent wiring is required as specified in the NEC®1
  • - Suitable for direct burial in earth at conductor remperatures not to exceed 90 Celsuis Degrees. 
  • - Voltage rating is 600V
  • - Three sizes available (with and without reduced neutral): 100, 150, and 200 ampere ratings.

 

Standards & References:

Individual conductors of Joysense Mobile Home Feeder assembly meet or exceed UL Standard 44, UL Standard 854, Federal Specfication A-A-59544, and requirements of the NEC®. 

 

Construction:

Joysense Mobile Home Feeder consists of four quadruplexed type RHH or RHW-2 or USE-2 with AA-8000 series Aluminum Alloy compacted conductors. The cable contains a triple extruded white strped neutral conductor and a solid green grounding conductor to elimiate the need for field marking per the NEC®. Insulation is sunlight resistant.

 

Recommended Sample Specifications:

Cable shall be UL-listed Type RHH or RHW-2 or USE-2, suitable for direct burial and operation at 600V. Conductors shall be Aluminum Alloy as manufactured by Joysense Company or approved equal. The calbe shall contain a triple extruded white striped neutral conductor and a sold green grounding conductor to eliminate the need for field marking per the NEC®.

 

 

WEIGHTS, MEASUREMENTS AND PACKAGING

CONDUCTOR

SIZE

(AWG or kcmil)

PHASE CONDUCTOR

NEUTRAL CONDUCTOR

GROUNDING CONDUCTOR

COMPLETE

CABLE

O.D.(mils)

WELGHT

 PER 1000ft

(lbs)

ALLOWABLE

AMPACITY

STD.

PKG

(ft)

SIZE&

CONST.

INS.

THICK

(mils)

DIA.

(mils)

SIZE&

CONST.

INS.

THICK

(mils)

DIA.

(mils)

SIZE&

CONST.

INS.

THICK

(mils)

DIA.

(mils)

2-2-4-6

2-7

60

391

4-7

60

336

6-7

60

292

944

305

100

500

2-2-2-4

2-7

60

391

2-7

60

391

4-7

60

336

944

351

100

500

2/0-2/0-1-4

2/0-18

80

539

1-18

80

462

4-7

60

336

1301

561

150

500

2/0-2/0-2/0-1

2/0-18

80

539

2/0-18

80

539

1-18

80

462

1301

679

150

500

4/0-4/0-2/0-4

4/0-18

80

638

2/0-18

80

539

4-7

80

462

1540

793

200

500

4/0-4/0-4/0-2/0

4/0-18

80

638

4/0-18

80

638

2/0-18

80

539

1540

999

200

500

Dwelling-For units, conductors shall be permitted at listed ampacities as 120/240 volt, 3-wire, single-phase services and feeders.

All conductors are compact stranded construction complying with UL standard 44.