产品中心
北京市朝阳区霞光里15号霄云中心B座1905室
电话: 010-84519511 、84519122
传真: 010-84514688
邮箱: info@luminovogroup.com
Underground (UD) : Aluminum Alloy Cable Series
日期: 2014/9/23 15:22:26    点击量:

 

 

Product Profile: 

  • - 600 Volt
  • - Aluminum Alloy (AA-8176) Conductor
  • - Cross-linked Polyethylene (XLP) Insulation
  • - High-Heat and Moisture Resistant
  • - Black Sizes 2 AWG and Larger Sunlight Resistant

 

Manufacturer: Joy Sense - World Fourth Largest Aluminum Alloy Cable Manufacturer

 

Applicaitons:

The product can be installed as general purpose building wire, used in service entrance, feeders and branch circuits applications for residential, commercial, indusrial and transportation environments for permanent installations utilizing 600 volts or less. Suitable for directly buried installations or ducts and can be used in environments where superior insulation toughness and chemical resistance is required. The product high resistance to humidity makes this cable suitable for wet locaiton, for outdoors and for weather resistant use.

 

Standards & References:

Secondary UD single conductor 600V cable meets or exceeds the following ASTM specifcation

  • - B-230 Aluminum Wire, 1350 H-19 for Electrical Purposes
  • - B-231 Aluminum 1350 Conductors, Concentric - Lay - Stranded
  • - UL 854 (For USE-2) 

 

Installation:

USE - 2 cable can be installed in electrical metallic tubing, PVC conduits and other raceways, in free air messenger support or directly buried. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by deficiencies in the installation.

 

 

 
SINGLE  CONDUCTOR  600V  UD

Conductor

Conductor

Diameter

(mils)

Insulation

Thickness

(mils)

Nominal

O.D.
(mils)

Allowable Ampacities**

Approx.

Net Weight

Per 1000 feetlbs

Standard

Package

(feet/reel)

Code

wore

Size

(AWG/kcmil)

Number of

Wires**

60

75

90

Princeton

6

7

169

60

289

40

50

70

45

1000

Mercer

4

7

213

60

333

55

65

85

64

1000

Clemson

2

7

268

60

388

75

90

110

93

1000

Kenyon

1

19

299

80

459

85

100

120

122

1000

Harvard

1/0

19

337

80

497

100

120

150

147

1000

Yale

2/0

19

377

80

537

115

135

165

179

1000

Tufts

3/0

19

425

80

585

130

155

190

218

1000

Beloit

4/0

19

476

80

636

150

180

225

266

1000

Hofstra

250

37

520

95

710

170

205

250

318

1000

Gonzaga

300

37

571

95

761

190

230

275

373

1000

Rutgers

350

37

618

95

808

210

250

305

428

1000

Dartmouth

400

37

657

95

847

225

270

330

481

1000

Emory

500

37

736

95

926

260

310

380

587

1000

Furman

700

61

878

110

1098

310

375

460

815

1000

Sewanee

750

61

906

110

1126

320

385

470

867

1000

Fordham

1000

61

1059

110

1279

375

445

540

1130

1000

Ampacity:90 conductor temperature, 20 ambient, RHO 90, 100% load factor for three conductor triplex with neutral carring only unbalanced load.Also available in paralleled construction.The above data is approximate and subject to normal manufacturing tolerances.

 

 

 

 

Conductor: Stranded, compressed 1350-H19 aluminum insulated with Cross-linked Polyethylene(XLPE). Neutrals are identified with triple solid yellow stripes. One phase conductor and one neutral conductor cabled together.

 

APPLICATIONS

The 600V Secondary UD Duplex Cable is mainly used for secondary distribution and underground service either direct burial or in ducts, The cable is designed for use at 600 volts or less.

STANDARDS/TESTING&SPECIFICATIONS

Secondary UD single conductor 600V cable meets or exceeds the following  ASTM specification.

·         B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.

·         B-231 Aluminum 1350 Conductors, Concentric-Lay-Stranded. Secondary UD duplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.

·         “ USE-2 ”per UL 854 available upon request.

INSTALLATION

For secondary distribution and underground service either direct burial or in ducts.

 

Secondary UD Duplex 600V

Code

Word

Phase Conductor

Neutral

Diameter

Approx.

Net Weight

lbs/1000ft

Allowable

Ampacities

(Raceway,

Cable,Ducts)

Size

Number of

Wires

Insulation

Thickness

Size

(AWG)

Number of

Wires

Insulation

Thickness

(in)

Single

Phase

Conductor(in)

Complete

Cable

(in)

DUPLEXED WITH TRIPLE SOLID YELLOW STRIPES NEUTRAL

Clafin

6

7

0.060

6

7

0.060

0.298

0.596

91

70

Delgado

4

7

0.060

4

7

0.060

0.344

0.688

129

110

Aluminum Conductor Cross-linked Polyethylene(XLPE) Insulation, one phase with neutral.90 conductor temperature, 20 ambient, RHO 90, 100% load factor .The above data is approximate and subject to normal manufacturing tolerances.

 

 

 

 

Conductor: Stranded, compressed 1350-H19 aluminum insulated with Cross-linked Polyethylene(XLPE).

Neutrals are identified with triple solid yellow stripes. Tow phase conductor and one neutral conductor cabled together.

APPLICATIONS

The 600V Secondary UD Triplex Cable is mainly used for secondary distribution and underground service either direct burial or in ducts, The cable is designed for use at 600 volts or less.

STANDARDS/TESTING&SPECIFICATIONS

Secondary UD single conductor 600V cable meets or exceeds the following  ASTM specification.

·         B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.

·         B-231 Aluminum 1350 Conductors, Concentric-Lay-Stranded. Secondary UD triplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.

·         " USE-2"per UL 854 available upon request.

INSTALLATION

For secondary distribution and underground service either direct burial or in ducts.

 

 

Secondary UD Triplex 600V

Code

Word

Phase Conductor

Neutral

Diameter

Approx.

Net Weight

lbs/1000ft

Allowable

Ampacities

(Raceway,

Cable,Ducts)

Size

Number of

Wires

Insulation

Thickness

Size

(AWG)

Number of

Wires

Insulation

Thickness

(in)

Single

Phase

Conductor(in)

Complete

Cable

(in)

TRIPLEXED WITH TRIPLE SOLID YELLOW STRIPES NEUTRAL

Erskine

6

7

0.060

6

7

0.060

0.298

0.642

135

60

Vassar

4

7

0.060

4

7

0.060

0.344

0.742

193

75

Stephens

2

7

0.060

4

7

0.060

0.344

0.869

525

110

Ramapo

2

7

0.060

2

7

0.060

0.403

0.869

282

110

Brenau

1/0

19

0.080

2

7

0.060

0.403

1.123

392

150

Bergen

1/0

19

0.080

1/0

19

0.080

0.521

1.123

447

150

Converse

2/0

19

0.080

1

19

0.080

0.482

1.217

486

165

Hunter

2/0

19

0.080

2/0

19

0.080

0.565

1.217

543

165

Hollins

3/0

19

0.080

1/0

19

0.080

0.521

1.324

589

190

Rockland

3/0

19

0.080

3/0

19

0.080

0.614

1.324

660

190

Sweetbriar

4/0

19

0.080

2/0

19

0.080

0.565

1.447

719

225

Monmouth

4/0

19

0.080

4/0

19

0.080

0.672

1.447

807

225

Pratt

250

19

0.095

3/0

19

0.095

0.614

1.610

864

250

Wesleyan

350

37

0.095

4/0

19

0.095

0.672

1.833

1133

305

Newark

350

37

0.095

350

37

0.095

0.896

1.931

1459

305

Holyoke

500

37

0.095

300

37

0.095

0.801

2.112

1562

380

Rider

500

37

0.095

350

37

0.095

0.850

2.112

1617

380

Seton Hall

750

61

0.110

750

61

0.110

1.190

2.564

2626

470

Ampacity:90 conductor temperature, 20 ambient, RHO 90, 100% load factor for three conductor triplex with neutral caring only unbalanced load. Also available in paralleled construction. The above data is approximate and subject to normal manufacturing tolerances.

 

 

 

Conductor: Stranded, compressed 1350-H19 aluminum insulated with Cross-linked Polyethylene(XLPE).

Neutrals are identified with triple solid yellow stripes. Three phase conductors and one neutral conductor cabled together.

 

APPLICATIONS

The Quadruplex 600V Secondary UD Cable is mainly used for secondary distribution and underground service either direct burial or in ducts, The cable is designed for use at 600 volts or less.

STANDARDS/TESTING&SPECIFICATIONS

Secondary UD single conductor 600V cable meets or exceeds the following  ASTM specification.

·         B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.

·         B-231 Aluminum 1350 Conductors, Concentric-Lay-Stranded. Secondary UD triplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.

·         " USE-2 "per UL 854 available upon request.

INSTALLATION

For secondary distribution and underground service either direct burial or in ducts.

 

Secondary UD Quadruplex 600V

Code

Word

Phase Conductor

Neutral

Diameter

Approx.

Net Weight

lbs/1000ft

Allowable

Ampacities

(Raceway,

Cable,Ducts)

Size

Number of

Wires

Insulation

Thickness

Size

(AWG)

Number of

Wires

Insulation

Thickness

(in)

Single

Phase

Conductor(in)

Complete

Cable

(in)

QUADRUPLEXED WITH TRIPLE SOLID YELLOW STRIPES NEUTRAL

Tulsa

4

7

0.060

4

7

0.060

0.344

0.831

259

85

Dyke

2

7

0.060

4

7

0.060

0.403

0.973

348

110

Wittenberg

2

7

0.060

2

7

0.060

0.403

0.973

378

110

Notre Dame

1/0

19

0.080

2

7

0.060

0.521

1.258

544

150

Purdue

1/0

19

0.080

1/0

19

0.080

0.521

1.258

600

150

Syracuse

2/0

19

0.080

1

19

0.080

0.565

1.363

671

165

Lafayette

2/0

19

0.080

2/0

19

0.080

0.565

1.363

728

165

Swarthmore

3/0

19

0.080

1/0

19

0.080

0.614

1.483

813

190

Davidson

3/0

19

0.080

3/0

19

0.080

0.614

1.483

885

190

McPherson

4/0

19

0.080

2

19

0.080

0.672

1.621

899

225

Wake Forest

4/0

19

0.080

2/0

19

0.080

0.672

1.621

993

225

Earlham

4/0

19

0.080

4/0

19

0.080

0.672

1.621

1081

225

Rust

250

37

0.095

3/0

19

0.080

0.747

1.804

1216

250

Slippery Rock

350

37

0.095

4/0

19

0.080

0.850

2.053

1563

305

Wofford

500

37

0.095

350

37

0.095

0.980

2.366

2218

380

Westminster

750

61

0.110

350

37

0.095

1.190

2.873

3069

470

Ampacity:90 conductor temperature, 20 ambient, RHO 90, 100% load factor for three conductor triplex with neutral caring only unbalanced load. Also available in paralleled construction. The above data is approximate and subject to normal manufacturing tolerances.