Product Profile:
- - Lightweight Aluminum Interlock Armor
- - 600 Volt
- - Aluminum Alloy 8000 Series (AA-8176) Conductors
- - (XLPE) Insulated Singles Rated XHHW-2
- - Bare Aluminum Alloy Grounding Conductor
Manufacturer: Joy Sense - World Fourth Largest Aluminum Alloy Cable Manufacturer
Applicaitons:
- - Branch, feeder and service power distribution under high ambient temperatures in commercial, industrial, institutional, and multi-residential buildings
- - Power, lighting, control, and signal circuits
- - Fished or embedded in plaster
- - Concealed or exposed installations
- - Environmental air-handling spaces per NEC©300.22(c)
- - Places of Assembly per NEC®518.4 and theaters per NEC®520.5
- - As aerial cable on a messenger
- - Installation in cable tray and approved raceways
- - Under raised floors for infomration techonlogy equipment conductors and cables per NEC®645.5(D)&645.(D)(2)
- - Class I Div. 2, Class II Div. 2, Class III Div.1 Hazadous Locations
Standards & References:
Joysense Aluminum Type MC Cable is conducted with Type XHHW-2 conductors rated 90 celsius degrees wet or dry, and a bare equipment grounding conductor. The conductors are AA-8000 series Aluminum Alloy compact stranded. A binder tape is wrapped over the conductors with interlocked aluminum tap applied over the assembly. Aluminum interlocking armor is applied over the assembly. Refer to color chart for conductor color sequence.
Features:
- - UL Classified 1, 2, and 3 Hour Through - Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038
- - Cable reserves wound on reel for ease of pulling and installation. When pulling from coils, pull from inside to ensure ease of installation
- - Anti-short bushings are not required for use with MC cable per the NEC® and UL
WEIGHTS,MEASUREMENTS AND PACKAGING |
|||||
Conductor Size(AWG/kcmil) |
Sub Assembly(inches) |
Overall Nominal Diameter(inches) |
Approx.Net Weight Per 1000(lbs) |
Allowable Ampacity (wet or dry) |
|
75℃ |
95℃ |
||||
THREE CONDUCTOR With Ground |
|||||
6-6-6-6 |
0.57 |
0.78 |
237 |
50 |
60 |
4-4-4-6 |
0.66 |
0.88 |
298 |
65 |
75 |
2-2-2-6 |
0.78 |
1.00 |
411 |
90 |
100 |
1-1-1-4 |
0.89 |
1.11 |
496 |
100 |
115 |
1/0-1/0-1/0-4 |
0.97 |
1.19 |
578 |
120 |
135 |
2/0-2/0-2/0-4 |
1.06 |
1.27 |
678 |
135 |
150 |
3/0-3/0-3/0-4 |
1.16 |
1.38 |
833 |
155 |
175 |
4/0-4/0-4/0-2 |
1.27 |
1.59 |
1089 |
180 |
205 |
250-250-250-2 |
1.42 |
1.73 |
1275 |
205 |
230 |
250-250-250-3/0 |
1.58 |
1.90 |
1400 |
205 |
230 |
350-350-350-1 |
1.62 |
1.94 |
1653 |
250 |
280 |
400-400-400-1 |
1.72 |
2.04 |
1830 |
270 |
305 |
500-500-500-3/0 |
1.88 |
2.20 |
2177 |
310 |
350 |
500-500-500-2/0 |
1.88 |
2.20 |
2224 |
310 |
350 |
500-500-500-1 |
1.88 |
2.20 |
2257 |
310 |
350 |
600-600-600-1/0 |
2.1 |
2.42 |
2608 |
340 |
385 |
750-750-750-3/0 |
2.3 |
2.62 |
3118 |
385 |
435 |
750-750-750-1/0 |
2.3 |
2.62 |
3177 |
385 |
435 |
FOUR CONDUCTOR With Ground |
|||||
2-2-2-2-4 |
0.87 |
1.09 |
508 |
72 |
80 |
1-1-1-1-4 |
0.99 |
1.21 |
619 |
80 |
92 |
1/0-1/0-1/0-1/0-4 |
1.08 |
1.30 |
727 |
96 |
108 |
2/0-2/0-2/0-2/0-4 |
1.18 |
1.40 |
858 |
108 |
120 |
3/0-3/0-3/0-3/0-4 |
1.30 |
1.61 |
1138 |
124 |
140 |
4/0-4/0-4/0-4/0-2 |
1.42 |
1.74 |
1374 |
144 |
164 |
250-250-250-250-3/0 |
1.58 |
1.90 |
1634 |
164 |
184 |
250-250-250-250-1 |
1.77 |
2.09 |
1746 |
164 |
184 |
350-350-350-350-1/0 |
1.82 |
2.19 |
2129 |
200 |
224 |
500-500-500-500-3/0 |
2.11 |
2.42 |
2877 |
248 |
280 |
600-600-600-600-3/0 |
2.34 |
2.66 |
3415 |
272 |
308 |
750-750-750-750-3/0 |
2.57 |
2.89 |
4089 |
308 |
348 |
750-750-750-750-750 |
2.89 |
3.20 |
4596 |
308 |
348 |
750-750-750-750-900 |
2.89 |
3.21 |
4837 |
308 |