产品中心
北京市朝阳区霞光里15号霄云中心B座1905室
电话: 010-84519511 、84519122
传真: 010-84514688
邮箱: info@luminovogroup.com
Aluminum Type MC : Aluminum Alloy Cable Series
日期: 2014-05-28 22:12:05    点击量:

 

Product Profile: 

  • - Lightweight Aluminum Interlock Armor
  • - 600 Volt
  • - Aluminum Alloy 8000 Series (AA-8176) Conductors
  • - (XLPE) Insulated Singles Rated XHHW-2
  • - Bare Aluminum Alloy Grounding Conductor

 

Manufacturer: Joy Sense - World Fourth Largest Aluminum Alloy Cable Manufacturer

 

Applicaitons:

  • - Branch, feeder and service power distribution under high ambient temperatures in commercial, industrial, institutional, and multi-residential buildings
  • - Power, lighting, control, and signal circuits
  • - Fished or embedded in plaster
  • - Concealed or exposed installations
  • - Environmental air-handling spaces per NEC©300.22(c)
  • - Places of Assembly per  NEC®518.4 and theaters per NEC®520.5
  • - As aerial cable on a messenger
  • - Installation in cable tray and approved raceways
  • - Under raised floors for infomration techonlogy equipment conductors and cables per NEC®645.5(D)&645.(D)(2)
  • - Class I Div. 2, Class II Div. 2, Class III Div.1 Hazadous Locations

 

Standards & References:

Joysense Aluminum Type MC Cable is conducted with Type XHHW-2 conductors rated 90 celsius degrees wet or dry, and a bare equipment grounding conductor. The conductors are AA-8000 series Aluminum Alloy compact stranded. A binder tape is wrapped over the conductors with interlocked aluminum tap applied over the assembly. Aluminum interlocking armor is applied over the assembly. Refer to color chart for conductor color sequence.

 

Features:

  • - UL Classified 1, 2, and 3 Hour Through - Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038 
  • - Cable reserves wound on reel for ease of pulling and installation. When pulling from coils, pull from inside to ensure ease of installation
  • - Anti-short bushings are not required for use with MC cable per the NEC® and UL

 

 

WEIGHTS,MEASUREMENTS AND PACKAGING

Conductor Size(AWG/kcmil)

Sub Assembly(inches)

Overall Nominal Diameter(inches)

Approx.Net Weight Per 1000(lbs)

Allowable Ampacity

(wet or dry)

75

95

THREE CONDUCTOR With Ground

6-6-6-6

0.57

0.78

237

50

60

4-4-4-6

0.66

0.88

298

65

75

2-2-2-6

0.78

1.00

411

90

100

1-1-1-4

0.89

1.11

496

100

115

1/0-1/0-1/0-4

0.97

1.19

578

120

135

2/0-2/0-2/0-4

1.06

1.27

678

135

150

3/0-3/0-3/0-4

1.16

1.38

833

155

175

4/0-4/0-4/0-2

1.27

1.59

1089

180

205

250-250-250-2

1.42

1.73

1275

205

230

250-250-250-3/0

1.58

1.90

1400

205

230

350-350-350-1

1.62

1.94

1653

250

280

400-400-400-1

1.72

2.04

1830

270

305

500-500-500-3/0

1.88

2.20

2177

310

350

500-500-500-2/0

1.88

2.20

2224

310

350

500-500-500-1

1.88

2.20

2257

310

350

600-600-600-1/0

2.1

2.42

2608

340

385

750-750-750-3/0

2.3

2.62

3118

385

435

750-750-750-1/0

2.3

2.62

3177

385

435

FOUR CONDUCTOR With Ground

2-2-2-2-4

0.87

1.09

508

72

80

1-1-1-1-4

0.99

1.21

619

80

92

1/0-1/0-1/0-1/0-4

1.08

1.30

727

96

108

2/0-2/0-2/0-2/0-4

1.18

1.40

858

108

120

3/0-3/0-3/0-3/0-4

1.30

1.61

1138

124

140

4/0-4/0-4/0-4/0-2

1.42

1.74

1374

144

164

250-250-250-250-3/0

1.58

1.90

1634

164

184

250-250-250-250-1

1.77

2.09

1746

164

184

350-350-350-350-1/0

1.82

2.19

2129

200

224

500-500-500-500-3/0

2.11

2.42

2877

248

280

600-600-600-600-3/0

2.34

2.66

3415

272

308

750-750-750-750-3/0

2.57

2.89

4089

308

348

750-750-750-750-750

2.89

3.20

4596

308

348

750-750-750-750-900

2.89

3.21

4837

308

348